Scientific publications
E. Martinez-Enriquez, G. Velarde-Rodríguez, N. Alejandre-Alba, D. Ansah, S. Kishore, A. de la Peña et al.
Postoperative intraocular lens tilt from preoperative full crystalline lens geometry using machine learning
Biomedical Optics Express 16, 1439-1456 (2025)

V. Rodriguez, C. Dorronsoro, A. de Castro
A metric-based image-formation model explains the improvement in subjective refraction using temporal defocus waves
Optometry and Vision Science 102(4): 196-203 (2025)
P. Papadogiannis, E. Gambra, G. Łabuz, W. Yan, D. Martín-Becerra, I. Sisó-Fuertes, A. de Castro, X. Barcala, G.U. Auffarth, C. Dorronsoro, L. Sawides
Visual simulation of intraocular lenses: from on-bench performance to computational and experimental validations
Biomedical Optics Express Vol. 15, Issue 11, pp. 6521-6530 (2024)
L. Villegas, F. Zvietcovich, S. Marcos, J.S. Birkenfeld
Revealing regional variations in scleral shear modulus in a rabbit eye model using multi-directional ultrasound optical coherence elastography
Scientific Reports Vol. 14, 21010 (2024)
R. Gutierrez-Contreras, M. Fernandez-Gutierrez, P. Olalla-Perez, A. De La Hoz, S. Marcos
Comparative Analysis of Silk Fibroin Membranes across Cross-Linking Methods: Processing and Characterization
ACS Omega 9, 37, 38452–38461 (2024)
A. de la Hoz, L. Villegas, S. Marcos, J.S. Birkenfeld
A simple computational model for scleral stiffness assessments via air-puff deformation OCT
Frontiers in Bioengeneering and Biotechnology, Sec. Biomechanics Vol. 12 (2024)
L. Villegas, J.A. Germann, S. Marcos
Effects of Different Scleral Photo-Crosslinking Modalities on Scleral Stiffness and Hydration
Investigative Ophthalmology & Visual Science, Vol. 65, 8 (2024)
A. Ruiz-Calvo, D. Ansah, U. Celik, S. MacRae, S. Marcos, E. Martínez-Enríquez
Automatic segmentation and quantification of OCT images before and after cataract surgery using deep learning
Applied Optics 63, 5376-5386 (2024)
E. Martínez-Enríquez, A. de Castro, M. Ruggeri, F. Manns, S. Marcos
Crystalline Lens Optics
Reference Module in Neuroscience and Biobehavioral Psychology, Elsevier, ISBN 9780128093245 (2024)
E. Esteban-Ibañez, D. Montagud-Martínez, L. Sawides, A. Zaytouny, A. de Castro, I. Sisó-Fuertes, X. Barcala, D. P. Piñero, W.D. Furlan, C. Dorronsoro & E. Gambra
Simulation of daily soft multifocal contact lenses using SimVis Gekko: from in-vitro and computational characterization to clinical validation
Scientific Reports 14, 8592 (2024)
M.P. Urizar, E. Gambra, A. de Castro, A. de la Peña, D. Pascual, O. Cetinkaya, S. Marcos, A. Curatolo
Long-range frequency-domain optical delay line based on a spinning tilted mirror for low-cost ocular biometry
Biomedical Optics Express 14, 6521-6541 (2023)
C.M. Lago; A. de Castro; S. Marcos
Computational simulation of the optical performance of an EDOF intraocular lens in post-LASIK eyes
A. de las Heras, A.I. Gómez-Varela, M.Baralida Tomás, R.A. Perez-Herrera, L. Alberto Sánchez, F. Gallazzi, B. Santamaría Fernández, M. Garcia-Lechuga, M. Vinas-Pena, M. Delgado-Pinar, V. González-Fernández
Innovative Approaches for Organizing an Inclusive Optics and Photonics Conference in Virtual Format
Optics, 4(1), 156-170 (2023)
M.P. Urizar, E. Gambra, A. de Castro, A. de la Peña, O. Cetinkaya, S. Marcos, A. Curatolo
Optical beam scanner with reconfigurable non-mechanical control of beam position, angle, and focus for low-cost whole-eye OCT imaging
Biomedical Optics Express 14, 4468-4484 (2023)
A. de la Hoz, E. Martínez-Enríquez, S. Marcos
Estimation of crystalline lens material properties from patient accommodation data and finite element models
Investig. Ophthalmol. Vis. Sci, 64/11 (2023)
E. Martínez-Enríquez, B. Maceo Heilman, A. de Castro, A. Mohamed, M. Ruggeri, F. Zvietcovich, F. Manns, S. Marcos
Estimation of the full shape of the crystalline lens from OCT: validation using stretched donor lenses
Biomedical Optics Express 14, 4261-4276 (2023)
V. Rodriguez-Lopez, A. Hernandez-Poyatos, C. Dorronsoro
Defocus flicker of chromatic stimuli deactivates accommodation
Biomedical Optics Express 14, 3671-3688 (2023)
V. Rodriguez-Lopez, W. Geisler, C. Dorronsoro
Spatiotemporal defocus sensitivity function of the human visual system
Biomedical Optics Express 14, 3654-3670 (2023)
V. Rodriguez-Lopez, C. Dorronsoro
Case report of the evidence of a spontaneous Reverse Pulfrich effect in monovision after cataract surgery
BMC Ophthalmology 23, 289 (2023)
A. K. Dickey, L. Rebeiz, H. Raef, R. K. Leaf, S. Elmariah, H. Naik, K. Anderson, J. Conley, C. Iyasere, S. Zhao, J. S. Birkenfeld et al.
Prospective observational pilot study of quantitative light dosimetry in erythropoietic protoporphyria
Journal of the American Academy of Dermatology 88, no. 5, 1148-1151 (2023)
E. Martínez-Enríquez, A. Curatolo, A. de Castro, J.S. Birkenfeld, A.M. González, A. Mohamed, M. Ruggeri, F. Manns, F. Zvietcovich, S. Marcos.
Estimation of the full shape of the crystalline lens in-vivo from OCT images using eigenlenses
Monovision Correction Preference and Eye Dominance Measurements
Translational Vision Science & Technology Vol.12, 18 (2023)

A. de Castro, E. Martínez-Enríquez, S. Marcos
Effect of fixational eye movements in corneal topography measurements with optical coherence tomography
Biomedical Optics Express 14 (5), 2138-2152 (2023)

S. Aissati, C. Benedi-Garcia, M. Vinas, A. de Castro, S. Marcos
Matching convolved images to optically blurred images on the retina
Journal of Vision February 22, 12 (2022)

R. McAuley, A. Nolan, A. Curatolo, S. Alexandrov, F. Zvietcovich, A. Varea Bejar, S. Marcos, M. Leahy, J. S. Birkenfeld
Coaxial acoustic-based optical coherence vibrometry probe for the quantification of resonance frequency modes
Scientific Reports Vol. 12, 18834 (2022)

X. Barcala, A. Zaytouny, D. Rego-Lorca, J. Sanchez-Quiros, R. Sanchez-Jean, J.M. Martinez-de-la-Casa, C. Dorronsoro, S. Marcos
Visual simulations of presbyopic corrections through cataract opacification
Journal of Cataract & Refractive Surgery 49 (1), 34-43 (2022)

S. Vedhakrishnan, M. Vinas, C. Benedi-Garcia, P. Casado, S. Marcos
Visual performance with multifocal lenses in young adults and presbyopes
PLOS ONE 17(3): e0263659 (2022)

S. Marcos, P. Artal, D.A. Atchison, K. Hampson, R. Legras, L. Lundström, G. Yoon
Adaptive optics visual simulators
Biomed. Opt. Express 13, 6508-6532 (2022)

S. Vedhakrishnan, A. de Castro, M. Vinas, S. Aissati, S. Marcos
Accommodation through simulated multifocal optics
Biomedical Optics Express 13 (12), 6695-6710 (2022)

C.M. Lago, A. de Castro, C. Benedí-García, S. Aissati, S. Marcos
Evaluating the effect of ocular aberrations on the simulated performance of a new refractive IOL design
Biomedical Optics Express 13 (12), 6682-6694 (2022)

C. Benedi-Garcia, M. Vinas, C. Dorronsoro, S.A. Burns, E. Peli, S. Marcos
Vision is protected against blue defocus
Scientific Reports 11, 352 (2021)

X. Barcala, M. Vinas, M. Romero, E. Gambra, J. L. Mendez-Gonzalez, S. Marcos, C. Dorronsoro
Multifocal acceptance score to evaluate vision MAS-2EV
Scientific Reports 11, 1397 (2021)

C. Benedi-Garcia, M. Vinas, C. M Lago, S. Aissati, A. de Castro, C. Dorronsoro, S. Marcos
Optical and visual quality of real intraocular lenses physically projected on the patient’s eye
Biomedical Optics Express Vol. 12, Issue 10, pp. 6360-6374 (2021)
Simulating Outcomes of Cataract Surgery: Important Advances in Ophthalmology

S. Marcos
Improving pseudophakic optical quality beyond aspheric intraocular lenses the next frontier
Journal of Cataract & Refractive Surgery Vol. 47 Issue 9 p 1111-1114 (2021)

J.A. Summers, F. Schaeffel, S. Marcos, H. Wu, A.V.Tkatchenkoe
Functional integration of eye tissues and refractive eye development mechanisms and pathways
Experimental Eye Research, 209, 108693 (2021)

D. Bronte-Ciriza, J.S. Birkenfeld, A. de la Hoz, A. Curatolo, J.A. Germann, L. Villegas, A. Varea, E. Martínez-Enríquez, S. Marcos
Estimation of scleral mechanical properties from air-puff optical coherence tomography
Biomedical Optics Express Vol. 12, Issue 10, pp. 6341-6359 (2021)

S. Marcos
Foveal aberrations and the impact on vision
Journal of Vision September 2021, Vol.21, 1805 (2021)

J.A. Germann, E. Martínez-Enríquez, M. Carmen Martínez-García, I.E. Kochevar, S. Marcos
Corneal Collagen Ordering After In Vivo Rose Bengal and Riboflavin Cross-Linking
Investigative Ophthalmology & Visual Science Vol.61, 28 (2020)

S. Marcos, M. Romero, C. Benedí-García, A. González-Ramos, M. Vinas, N. Alejandre, I. Jiménez-Alfaro
Interaction of monochromatic and chromatic aberrations in pseudophakic patients
Journal of Refractive Surgery Vol. 36, No. 4 (2020)

E. Martinez-Enriquez, A. de Castro, A. Mohamed, N. Geetha Sravani, M. Ruggeri, F. Manns, S. Marcos
Age-Related Changes to the Three Dimensional Full Shape of the Isolated Human Crystalline Lens
Investigative Ophthalmology & Visual Science Vol.61, 11 (2020)

A. de Castro, E. Martinez-Enriquez, P. Perez-Merino, M. Velasco Ocana, L. Revuelta, S. McFadden, S. Marcos
Crystalline lens gradient refractive index distribution in the guinea pig
Ophthalmic & Physiological Optics 40, 308–315 (2020)

M. Vinas, S. Aissati, A. Maria Gonzalez-Ramos, M. Romero, L. Sawides, V. Akondi, E. Gambra, C. Dorronsoro, T. Karkkainen, D. Nankivil, S. Marcos
Optical and Visual Quality With Physical and Visually Simulated Presbyopic Multifocal Contact Lenses
Translational Vision Science & Technology Vol.9, 20 (2020)

E. Martinez-Enriquez, A. de Castro, S. Marcos
Eigenlenses: a new model for full crystalline lens shape representation and its applications
Biomedical Optics Express 11 (10), 5633-5649 (2020)
S. Aissati, M. Vinas, C. Benedi-Garcia, C. Dorronsoro, S. Marcos
Testing the effect of ocular aberrations in the perceived transverse chromatic aberration
Biomedical Optics Express 11 (8), pp. 4052-4068 (2020)

S. Marcos, C. Benedí‐García, S. Aissati, A.M Gonzalez‐Ramos, C.M Lago, A. Radhkrishnan, M. Romero, S. Vedhakrishnan, L. Sawides, M. Vinas
VioBio lab adaptive optics: technology and applications by women vision scientists
Ophthalmic Physiol Opt 40, 75– 87 (2020)

A. Curatolo, J.S. Birkenfeld, E. Martinez-Enriquez, J.A. Germann, G. Muralidharan, J. Palací, D. Pascual, A. Eliasy, A. Abass, J. Solarski, K. Karnowski, M. Wojtkowski, A. Elsheikh, S. Marcos
Multi-meridian corneal imaging of air-puff induced deformation for improved detection of biomechanical abnormalities
Biomedical Optics Express Vol. 11, Issue 11, pp. 6337-6355 (2020)
More publications
C. Dorronsoro, X. Barcala, E. Gambra, V. Akondi, L. Sawides, Y. Marrakchi, V. Rodriguez-Lopez, C. Benedi-Garcia, M. Vinas, E. Lage, S. Marcos
Tunable lenses: dynamic characterization and fine-tuned control for high-speed applications
Visual simulators replicate vision with multifocal lenses
Scientific Reports Vol. 9, Article number: 1539 (2019)

A. de Castro, J. Birkenfeld, B. Maceo Heilman, M. Ruggeri, E. Arrieta, J.M. Parel, F. Manns and S. Marcos
Off-axis optical coherence tomography imaging of the crystalline lens to reconstruct the gradient refractive index using optical methods
Biomedical Optics Express Vol. 10, Issue 7, pp. 3622-3634 (2019)

J. Burge, V. Rodriguez-Lopez, C. Dorronsoro
Monovision and the Misperception of Motion

A. de la Hoz, J. Germann, E. Martinez-Enriquez, D. Pascual, N. Bekesi, N. Alejandre-Alba, C. Dorronsoro and S. Marcos
Design and ex situ performance of a shape-changing accommodating intraocular lens

M. Vinas, S. Aissati, M. Romero, C. Benedi-Garcia, N. Garzon, F. Poyales, C. Dorronsoro, and S. Marcos
Pre-operative simulation of post-operative multifocal vision

G. Muralidharan, E. Martínez-Enríquez, J. Birkenfeld, M. Velasco-Ocana, P. Pérez-Merino and S. Marcos
Morphological changes of human crystalline lens in myopia

C. Benedi-Garcia, M. Velasco-Ocana, C. Dorronsoro, D. Pascual, M. Hernandez, G. Marin, S. Marcos
Perceptual impact of astigmatism induction in presbyopes
Vision Research 165, 143–151 (2019)

Vision with different presbyopia corrections simulated with a portable binocular visual simulator

Quantization of collagen organization in the stroma with a new order coefficient

Estimation of intraocular lens position from full crystalline lens geometry: towards a new generation of intraocular lens power calculation formulas

P. Pérez-Merino, S. Marcos
Effect of intraocular lens decentration on image quality tested in a custom model eye

Intraocular Photobonding to Enable Accommodating Intraocular Lens Function

Experimental validations of a tunable-lens-based visual demonstrator of multifocal corrections

Rose Bengal and Green Light Versus Riboflavin–UVA Cross-Linking: Corneal Wound Repair Response

Vision science and adaptive optics, the state of the field

Comparison of vision through surface modulated and spatial light modulated multifocal optics

OCT-based full crystalline lens shape change during accommodation in vivo

Biomechanical Changes After In Vivo Collagen Cross-Linking With Rose Bengal–Green Light and Riboflavin-UVA

Three-dimensional OCT based guinea pig eye model: relating morphology and optics

Vyas Akondi, Pablo Pérez-Merino, Eduardo Martinez-Enriquez, Carlos Dorronsoro, Nicolás Alejandre, Ignacio Jiménez-Alfaro, and Susana Marcos
Evaluation of the True Wavefront Aberrations in Eyes Implanted With a Rotationally Asymmetric Multifocal Intraocular Lens

Temporal multiplexing to simulate multifocal intraocular lenses: theoretical considerations

Corneal Wound Repair After Rose Bengal and Green Light Crosslinking: Clinical and Histologic Study

In Vivo Measurement of Longitudinal Chromatic Aberration in Patients Implanted With Trifocal Diffractive Intraocular Lenses

Testing vision with angular and radial multifocal designs using Adaptive Optics

Differences in visual quality with orientation of a rotationally asymmetric bifocal intraocular lens design

Virtual pyramid wavefront sensor for phase unwrapping

Full 3-D OCT-based pseudophakic custom computer eye model

Corneal Biomechanical Response Following Collagen Cross-Linking With Rose Bengal–Green Light and Riboflavin-UVA

Optical Coherence Tomography Based Estimates of Crystalline Lens Volume, Equatorial Diameter, and Plane Position

Material Properties from Air Puff Corneal Deformation by Numerical Simulations on Model Corneas

Portable simultaneous vision device to simulate multifocal corrections

Perceived image quality with simulated segmented bifocal corrections

A cyclopean neural mechanism compensating for optical differences between the eyes

Changes in Monkey Crystalline Lens Spherical Aberration During Simulated Accommodation in a Lens Stretcher

Single neural code for blur in subjects with different interocular optical blur orientation

Impact of astigmatism and high-order aberrations on subjective best focus

Toward New Engagement Paradigms For Intraocular Lenses: Light-Initiated Bonding of Capsular Bag to Lens Materials

Astigmatism of the Ex Vivo Human Lens: Surface and Gradient Refractive Index Age-Dependent Contributions

Phase unwrapping with a virtual Hartmann-Shack wavefront sensor

OCT-based crystalline lens topography in accommodating eyes

In vivo subjective and objective longitudinal chromatic aberration after bilateral implantation of the same design of hydrophobic and hydrophilic intraocular lenses

Design and Clinical Evaluation of a Handheld Wavefront Autorefractor

Longitudinal chromatic aberration of the human eye in the visible and near infrared from wavefront sensing, double-pass and psychophysics
Go to publications before 2015